Skip to main content
Skip table of contents

Configuring Bridge in Online Mode

The Bridge can be configured in two ways through the online mode. All added configurations work as long as the Bridge is running. Once the Bridge is stopped, all configurations are lost.

Configuring from the FMQ-JMX login

To configure the Bridge online, login to the Bridge through FMQ-JMX from the eStudio. The User can perform an RMI based JMX login to the Bridge from eStudio by providing the RMI Port.

After the FMQ-JMX login from eStudio, 

  1. Navigate to JMX Connection > Fiorano > Bridge > FioranoConnectorManager
  2. Right-click and select View Operations option.
  3. Select the addLink(LinkConfiguration) option from the FioranoConnectionManager dialog box.
     


  4. Invoke the addLink operation by assigning appropriate values to LinkConfiguration.



  5. Once the link is created, navigate to JMX Connection > Fiorano > Bridge > Link > LinkName. The LinkName is provided by the User when creating the link. (If the Link runtime MBean is not displayed via eStudio, right-click the Link to refresh it). Perform the addChannel operation by assigning appropriate values in the configuration wizard.
     


  6. The add channel 'function' is visible to the user at the end of performing the add channel operation. A User can modify the link configuration by performing the editLinkConfiguration operation. All offline operations can be performed here while corresponding operations are performed at appropriate locations.

Configuring from the FMQ login

To configure the StandAloneBridge through the FMQ login, 

  1. Change the RMI ConnectorPort to the port on which the Bridge is running. By default, the ConnectorPort is 1858. Change the ConnectorPort to 1899 for StandAloneBridge. Log into the FMQ server through eStudio.
     


  2. After logging into the FMQ server, right-click on the Bridge and click the Add Link option from the pop-up menu. The New Link Properties dialog box is displayed.
     



  3. Click the LinkConfiguration button to view link properties; all the required properties are shown on the property sheet.
     


  4. Add the appropriate values to the required properties. Server Advanced Params can remain empty. eStudio will display the new configurations.
  5. Right-click the new link and perform the add channel operation.
  6. Assign appropriate values through the input wizard. Properties are uneditable. Once the configuration is added, a User is unable to edit parameter values. If the User needs to alter these values then the link or the channel should be deleted and replaced with a link and/or a channel that has the required parameters.



JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.